3D orientation data – A comparison of diffraction contrast tomography and serial sectioning electron backscatter diffraction for the nickel-base superalloy IN738LC
- authored by
- Silvia Reschka, Gregory Gerstein, Sebastian Herbst, Lukas Munk, Peter Wriggers, Hans Jürgen Maier
- Abstract
For specimen characterization, X-ray microscopy offers a variety of advantages like non-destructive investigations and reduced preparation effort for the samples. Orientation measurements are possible using diffraction contrast tomography (DCT). However, lateral resolution is lower as compared to scanning electron microscopy combined with electron backscatter diffraction (EBSD). A sample of a nickel-based superalloy IN738LC was investigated three-dimensionally for direct comparison of EBSD and DCT, which clearly reveals the advantages, disadvantages and limits of both methods. Images obtained by EBSD showed more microstructural details, but also artefacts resulting from the previous sample preparation. DCT seemed more suitable for 3D-imaging, but was not able to resolve some of the smaller grains.
- Organisation(s)
-
Institute of Materials Science
Institute of Continuum Mechanics
- Type
- Article
- Journal
- Materials letters
- Volume
- 262
- ISSN
- 0167-577X
- Publication date
- 01.03.2020
- Publication status
- Published
- Peer reviewed
- Yes
- ASJC Scopus subject areas
- General Materials Science, Condensed Matter Physics, Mechanics of Materials, Mechanical Engineering
- Electronic version(s)
-
https://doi.org/10.1016/j.matlet.2019.127177 (Access:
Closed)
-
Details in the research portal "Research@Leibniz University"